BLDC Motor for Electric Forklifts & Pallet Jacks: Traction Drive, Hydraulic Pump & Steering Selection Guide

Electric forklifts and pallet jacks rely on three distinct motor systems working in concert: a traction drive motor for vehicle movement, a hydraulic pump motor for mast lift and tilt functions, and an EPS steering motor for power-assisted turning. Each motor has fundamentally different operating requirements — the traction motor must deliver high torque at low speed for loaded starts and ramp climbing, the pump motor must sustain high-speed operation at 1800–2500 RPM through hundreds of lift cycles per shift, and the steering motor must provide precise, instantaneous torque response for operator safety. This guide covers the complete BLDC motor selection process for electric forklifts from a manufacturer’s perspective — power sizing for each motor function, voltage selection from 24V through 80V, gear ratio optimization, regenerative braking integration, and a head-to-head comparison of BLDC versus AC induction versus brushed DC motor technologies for material handling equipment.

Three Motors, Three Jobs: Understanding Forklift Motor Architecture

Every electric forklift contains at least two motors; most contain three. Selecting the right BLDC motor for each function requires understanding the distinct duty cycle and performance envelope of each application.

Traction Drive Motor: Moving the Vehicle

The traction motor converts battery energy into vehicle motion. In Class III equipment (pallet jacks, walkie stackers), a single motor drives one or two wheels through a reduction gearbox. In Class I/II counterbalance forklifts, two traction motors in a differential drive configuration provide both propulsion and electronic steering assistance. The traction motor faces the most demanding duty cycle: continuous forward/reverse cycling with loaded starts (requiring 2–3× rated torque for breakaway), ramp climbing at 5–10% grade with full payload, and regenerative braking during deceleration. A typical warehouse traction motor accumulates 200–500 start-stop cycles per shift.

Hydraulic Pump Motor: Lifting the Load

The pump motor drives a gear pump or vane pump that pressurizes hydraulic fluid for mast lift, tilt, side-shift, and fork positioning. Unlike the traction motor, the pump motor operates in a binary pattern — it runs at near-constant speed (1800–2500 RPM) when any hydraulic function is active and stops completely when all functions are idle. The challenge is not speed control but rather high-cycle endurance: a busy forklift activates the pump motor 200–400 times per 8-hour shift, with each cycle lasting 3–15 seconds. Brushed DC pump motors in older forklifts require brush replacement every 2,000–4,000 hours — every 6–12 months in multi-shift operations.

EPS Steering Motor: Turning the Wheels

Electric Power Steering (EPS) motors assist the operator in turning the steer axle. These are low-power motors (200–500W) with extremely demanding response requirements: the motor must deliver full assist torque within 50–100 milliseconds of steering wheel input, and torque must be proportional to steering effort for intuitive feel. BLDC motors with Hall sensor feedback and FOC (Field-Oriented Control) have become the standard for EPS because they provide smooth, cogging-free torque at any shaft angle — critical for precise fork positioning during pallet engagement.

Electric Forklift Motor Functions at a Glance

Motor Function Power Range Speed Range Key Requirement Duty Cycle
Traction drive1.5–15 kW0–4000 RPMHigh breakaway torque, regen brakingS3 (intermittent, 200–500 cycles/shift)
Hydraulic pump2–7 kW1800–2500 RPMHigh-cycle endurance, constant speedS4 (intermittent + starts, 200–400 cycles/shift)
EPS steering0.2–0.5 kW0–3000 RPMInstant torque response (<100 ms)S1/S3 (continuous with load variation)

Traction Motor Power Sizing: 1.5 kW to 15 kW by Equipment Class

Traction motor sizing for forklifts follows the same physics as AGV motor sizing but at significantly higher power levels and with additional grade-climbing requirements mandated by forklift safety standards (ISO 3691, UL 2267).

The total traction force required at the drive wheel is: Ftotal = Frolling + Faccel + Fgradient

For forklifts, rolling resistance coefficients are higher than AGVs because of heavier pneumatic or cushion tires on rougher surfaces: 0.02–0.03 for cushion tires on smooth concrete, 0.03–0.05 for pneumatic tires on asphalt/rough concrete, and 0.05–0.08 for pneumatic tires on gravel or uneven outdoor surfaces.

Class III: Pallet Jacks & Walkie Stackers (1.5–3 kW)

Class III equipment carries 1–2 ton payloads at 5–8 km/h with a vehicle tare weight of 200–500 kg. A 1.5-ton electric pallet jack with a 300 kg tare, traveling at 6 km/h (1.67 m/s) on smooth concrete with 3% grade capability, requires approximately 1.8 kW per drive wheel. Shenghe’s BL120 series (500–2000W) at 24V or 48V with a planetary gearbox at 15:1–25:1 ratio is the standard fit. For walkie stackers with mast heights above 3 meters, the higher center of gravity during loaded travel requires enhanced low-speed stability — select motors with incremental encoders for FOC control.

Class I/II: Counterbalance Forklifts (4–15 kW)

Counterbalance forklifts (1.5–3.5 ton capacity) require 4–8 kW per traction motor in a dual-motor configuration, or 8–15 kW for a single-motor design with mechanical differential. A 2.5-ton forklift with an 1800 kg tare, targeting 16 km/h (4.44 m/s) on smooth concrete with 10% grade capability and 0.5 m/s² acceleration, requires approximately 12 kW total traction power. At 80V, this draws 167A at rated efficiency — within the capacity of standard 175A Anderson connectors and 2/0 AWG battery cables.

Peak torque requirements are critical for counterbalance forklifts. During a loaded start on a 10% grade, the motor must deliver 2.5–3× its rated continuous torque for 5–10 seconds. BLDC motors handle this through their inherent peak-to-continuous torque ratio of 3:1 to 4:1 (limited by controller current capacity and motor demagnetization threshold), significantly better than AC induction motors which typically achieve 2:1 to 2.5:1.

Traction Motor Sizing by Forklift Class

Equipment Type Capacity Traction Power Voltage Max Speed Grade Capability Drive Config
Electric pallet jack1–2 ton1.5–3 kW24V / 48V5–8 km/h3–5%Single motor
Walkie stacker1–1.6 ton2–4 kW24V / 48V5–8 km/h5–8%Single motor
Reach truck1.5–2.5 ton4–8 kW48V / 80V10–14 km/h8–12%Dual motor
Counterbalance (3-wheel)1.5–2 ton4–8 kW48V / 80V12–16 km/h10–15%Dual motor
Counterbalance (4-wheel)2–3.5 ton8–15 kW48V / 80V14–20 km/h10–18%Single + diff / Dual
Order picker0.5–1 ton2–4 kW24V / 48V8–12 km/h5–8%Dual motor

Hydraulic Pump Motor Selection: Power, Speed, and Coupling

The hydraulic pump motor is the second-highest power consumer in an electric forklift, typically drawing 30–50% of total battery energy over a shift. Selecting the right BLDC pump motor directly impacts lift speed, multi-function responsiveness, and battery runtime.

Pump Motor Power Sizing

Hydraulic pump motor power depends on system pressure, pump displacement, and target flow rate. The fundamental equation is: Ppump = (p × Q) / (600 × ηpump × ηmotor), where P is motor power in kW, p is system pressure in bar, Q is flow rate in L/min, and η values are pump and motor efficiencies.

Typical forklift hydraulic systems operate at 140–210 bar (2000–3000 PSI). A pallet jack with a single-stage mast needs 8–15 L/min flow, requiring 2–3 kW. A counterbalance forklift with a triple-stage mast running lift, tilt, and side-shift simultaneously needs 25–50 L/min, requiring 4–7 kW.

Direct Coupling vs Gearbox

Pump motors typically drive the hydraulic pump through a direct bell housing coupling (no gearbox) because gear pumps operate efficiently at 1800–2500 RPM — a speed range that BLDC motors reach at rated voltage without gear reduction. This simplifies the drivetrain: motor → coupling → pump, with no gearbox losses, no gearbox maintenance, and no gearbox noise. The motor is selected to match the pump’s rated speed directly. Shenghe’s pump-duty BLDC motors are available with SAE A 2-bolt or 4-bolt mounting flanges and splined or keyed output shafts compatible with standard forklift gear pump inputs.

BLDC Advantage: Variable-Speed Pump Control

A significant advantage of BLDC pump motors over brushed DC is variable-speed operation. Traditional forklift hydraulic systems run the pump motor at a fixed speed and regulate flow with proportional control valves — wasting energy as heat whenever flow demand is below maximum. A BLDC pump motor with FOC control adjusts motor speed to match actual flow demand, eliminating throttling losses. Field data from forklift OEMs shows 15–25% hydraulic energy savings with variable-speed BLDC pump drive versus fixed-speed brushed DC, translating directly to extended battery runtime.

Hydraulic Pump Motor Specifications by Equipment Type

Equipment Type Pump Motor Power Pump Speed System Pressure Flow Rate Coupling Type
Pallet jack (single-stage mast)2–3 kW1800–2200 RPM140–170 bar8–15 L/minDirect, SAE A 2-bolt
Walkie stacker3–4 kW2000–2400 RPM170–200 bar12–20 L/minDirect, SAE A 2-bolt
Reach truck4–5 kW2000–2500 RPM180–210 bar20–35 L/minDirect, SAE A 4-bolt
Counterbalance forklift5–7 kW2000–2500 RPM200–210 bar30–50 L/minDirect, SAE A 4-bolt

Voltage Selection: 24V vs 48V vs 80V for Forklift Systems

Forklift voltage selection is driven by total system power consumption and the equipment class. Unlike AGV systems where 24V and 48V cover nearly all applications, forklifts extend into 80V territory due to the higher power demands of traction and hydraulic functions operating simultaneously.

24V: Pallet Jacks and Light Stackers

24V systems are limited to equipment with total motor power (traction + pump + steering) under approximately 5 kW. A 1.5-ton pallet jack with a 2 kW traction motor and a 2.5 kW pump motor totals 4.5 kW, drawing a maximum of 208A at 24V during simultaneous travel and lift. This is at the upper limit of practical 24V wiring, requiring 1/0 AWG cables and 350A-rated connectors. The advantage is access to inexpensive, compact 24V lead-acid or lithium-ion battery packs and simpler, lower-cost controllers.

48V: Mid-Range Equipment

48V is the dominant voltage for walkie stackers, small reach trucks, and 3-wheel counterbalance forklifts with total motor power of 5–12 kW. At 48V, the same 4.5 kW pallet jack draws only 104A — half the current of 24V, reducing wiring losses by 75%. The broader benefit is compatibility with high-energy-density 48V LiFePO4 battery packs (10–30 kWh) that enable full-shift operation without opportunity charging.

80V: Heavy Counterbalance Forklifts

80V systems serve counterbalance forklifts with total motor power above 12 kW. A 3-ton forklift with 12 kW traction + 6 kW pump + 0.4 kW steering = 18.4 kW total draws 256A at 80V during peak operation. At 48V, the same system would draw 426A — requiring massive cables, generating excessive heat, and exceeding the rating of standard industrial connectors. 80V keeps peak current below 300A, compatible with DIN 80V multi-pin battery connectors standardized across the forklift industry.

Voltage System Comparison for Forklifts

Parameter 24V System 48V System 80V System
Total motor power range≤5 kW5–12 kW12–25 kW
Peak current (at max power)208A (5 kW)250A (12 kW)313A (25 kW)
Wiring gauge (main bus)1/0 AWG2 AWG4 AWG
Battery type (common)Lead-acid / Li-ionLiFePO4LiFePO4
Battery capacity range5–15 kWh10–30 kWh20–50 kWh
Regen braking efficiencyLowModerate (8–15%)High (12–20%)
Controller costLowestMediumHighest
Equipment class (typical)Class III pallet jackClass III stacker, Class I smallClass I/II counterbalance
Industry adoption trendDecliningGrowingStandard for 2+ ton

Regenerative Braking: Extending Forklift Battery Runtime

Regenerative braking is one of the strongest arguments for BLDC motors in electric forklifts. Forklifts operate in a uniquely favorable pattern for energy recovery: frequent stop-start cycles (200–500 per shift), moderate travel speeds (5–16 km/h), and a hydraulic system where gravitational potential energy can be recovered during mast lowering.

Traction Regeneration

When the operator releases the accelerator pedal, the BLDC controller transitions the traction motor from drive mode to generator mode. The motor’s back-EMF is rectified through the controller’s inverter bridge and fed back to the battery. The energy recovered per deceleration event depends on vehicle mass, speed, and deceleration rate. For a 4-ton forklift (loaded) decelerating from 12 km/h to zero, the recoverable kinetic energy is approximately 22 Wh per event. Over 300 deceleration events per shift, traction regen returns 4–7 kWh — equivalent to 30–50 additional minutes of operation on a 30 kWh battery pack.

Hydraulic Regeneration

During mast lowering, the loaded forks descend under gravity, pushing hydraulic fluid back through the system. In a conventional forklift, this energy is dissipated as heat through flow control valves. With a BLDC pump motor, the hydraulic flow drives the pump in reverse (as a motor), spinning the BLDC motor as a generator and recovering the gravitational potential energy. For a 2-ton load lowered 3 meters, the recoverable energy is approximately 58 Wh. With 100–200 lowering cycles per shift, hydraulic regen returns 3–8 kWh additional — a significant contribution to total energy recovery.

Combined traction and hydraulic regeneration typically extends battery runtime by 15–25% compared to non-regenerative systems, often eliminating the need for mid-shift battery swaps in warehouses where shift coverage was previously marginal.

Regenerative Energy Recovery by Forklift Type

Equipment Type Traction Regen (per shift) Hydraulic Regen (per shift) Total Regen Runtime Extension
Pallet jack (1.5 ton)0.5–1.5 kWh0.3–0.8 kWh0.8–2.3 kWh10–15%
Walkie stacker1.0–2.0 kWh1.5–3.0 kWh2.5–5.0 kWh12–18%
Reach truck2.0–4.0 kWh3.0–6.0 kWh5.0–10 kWh15–22%
Counterbalance (3 ton)4.0–7.0 kWh3.0–8.0 kWh7.0–15 kWh18–25%

Motor Technology Comparison: BLDC vs AC Induction vs Brushed DC for Forklifts

The electric forklift industry has undergone two motor technology transitions: from brushed DC to AC induction in the 2000s, and now from AC induction to BLDC (permanent magnet synchronous) starting in the 2020s. Understanding why BLDC is displacing AC induction — despite AC induction being the “modern” choice just a decade ago — requires examining the specific operating conditions of material handling equipment.

Why AC Induction Motors Fell Short

AC induction motors eliminated the brush maintenance problem of brushed DC and offered rugged, low-cost construction. However, they have an inherent efficiency disadvantage at partial load. An induction motor must continuously draw magnetizing current to create the rotor magnetic field (unlike a BLDC motor where permanent magnets provide the field for free). At full load, this magnetizing current is a small percentage of total current and efficiency is competitive (89–93%). But forklifts spend 60–70% of operating time at partial load — during slow positioning, empty travel, and idle with motor energized. At 25% load, induction motor efficiency drops to 70–80%, while BLDC efficiency stays at 85–90%. Over a full shift, this partial-load efficiency gap translates to 8–15% less battery runtime for induction-driven forklifts.

BLDC Advantages for Forklift OEMs

Beyond efficiency, BLDC motors offer forklift OEMs three compelling advantages: (1) 20–30% smaller motor volume for equivalent power, enabling more compact chassis designs and lower floor heights for pallet jacks; (2) superior low-speed torque with FOC control — full rated torque from zero RPM without the torque dip that plagues induction motors below 5–10% of rated speed; (3) precise speed control without tachometer — Hall sensors integrated in the motor provide inherent rotor position feedback, eliminating the external speed sensor required by induction motor vector drives.

Forklift Motor Technology Comparison

Parameter BLDC (PM Synchronous) AC Induction Brushed DC
Full-load efficiency90–95%89–93%78–85%
25% load efficiency85–90%70–80%60–70%
Power density (kW/kg)HighestMediumLowest
Motor volume (same power)Smallest30% larger50% larger
Torque at zero RPMFull rated (with FOC)Reduced (slip-dependent)Full rated
Peak-to-continuous torque3:1 – 4:12:1 – 2.5:12:1 (brush limit)
Service life20,000+ hours20,000+ hours2,000–4,000 hours
MaintenanceBearing onlyBearing onlyBrush + commutator
Regen braking efficiencyHighestGoodLimited
Controller complexityFOC inverterVector/V-f inverterChopper/contactor
Motor costHighest (magnets)LowLowest
Total cost of ownership (5 yr)LowestMediumHighest
Battery runtime (same kWh)Longest8–15% less15–30% less
Industry trend (2026)Growing rapidlyEstablished, plateauingLegacy only

Gear Ratio Selection for Forklift Traction Drives

Forklift traction motors connect to the drive wheel through a reduction gearbox that converts high motor speed (2000–4000 RPM) into low wheel speed (100–500 RPM) while multiplying torque. The gear ratio must balance top speed, torque for loaded starts, and efficiency.

Calculation Method

For a forklift with drive wheel diameter D (meters) and target top speed v (km/h), the required wheel RPM is: nwheel = (v × 1000) / (60 × π × D). The gear ratio is: i = nmotor_max / nwheel.

Example: 250 mm drive wheel, 12 km/h top speed, 3500 RPM motor. nwheel = (12 × 1000) / (60 × π × 0.25) = 254.6 RPM. Gear ratio = 3500 / 254.6 = 13.7:1. Select the nearest catalog ratio: 14:1.

Forklift gear ratios are typically lower than AGV gear ratios (10:1–25:1 vs 20:1–60:1) because forklift top speeds are higher (10–20 km/h vs 1–2 m/s for AGVs) and forklift motors are higher power with more torque available before gear reduction.

Gearbox Types for Forklift Traction

Helical gear reducers (94–97% efficiency per stage) are the most common choice for forklift traction due to their high efficiency, high load capacity, and quiet operation. Two-stage helical reducers at 10:1–25:1 ratio handle the full range of forklift traction requirements.

Planetary gearboxes (90–95% efficiency) offer more compact packaging for the same ratio but at higher cost. They are preferred for pallet jacks where the motor-gearbox assembly must fit within the narrow drive unit housing.

Right-angle gearboxes are used when the motor must be mounted perpendicular to the drive axle — common in steer-drive configurations where the entire motor-gearbox-wheel assembly rotates for steering.

Forklift Traction Gear Ratio Quick Reference

Wheel Diameter Top Speed Wheel RPM Gear Ratio (3500 RPM motor) Typical Equipment
200 mm6 km/h159 RPM22:1Pallet jack
200 mm8 km/h212 RPM16.5:1Walkie stacker
250 mm12 km/h255 RPM13.7:1Reach truck
300 mm14 km/h248 RPM14.1:13-wheel counterbalance
350 mm16 km/h243 RPM14.4:14-wheel counterbalance
400 mm20 km/h265 RPM13.2:1Outdoor counterbalance

Shenghe BLDC Motors for Forklift & Pallet Jack Applications

Shenghe manufactures BLDC gear motors from 30W to 2000W that serve as traction drives for Class III pallet jacks, walkie stackers, and small-capacity material handling equipment, as well as hydraulic pump motors and EPS steering motors across all forklift classes.

Traction Motor Solutions

For pallet jacks and walkie stackers requiring 1.5–3 kW traction power, Shenghe’s BL120 series provides the ideal combination of high continuous torque, compact dimensions, and thermal endurance. The BL120 at 48V with a planetary gearbox at 15:1–20:1 ratio delivers 80–120 N·m output torque with peak capability of 300+ N·m for loaded starts. Class F insulation (155°C) ensures reliable operation under the S3 intermittent duty cycle of forklift traction.

Pump Motor Solutions

For hydraulic pump applications requiring 2–4 kW, the BL104 series and BL120 series are configured with SAE-compatible mounting flanges and high-speed rated bearings (rated for 3000+ RPM continuous). No gearbox is needed — the motor couples directly to the gear pump through a standard bell housing.

Steering Motor Solutions

For EPS steering assist requiring 200–500W, the BL90 series with integrated Hall sensors and matched FOC controller provides the smooth, cogging-free torque delivery essential for precise steering feel. Low inertia rotor design ensures <80 ms torque response time.

Custom OEM Integration

For forklift OEMs with annual volumes above 500 units, Shenghe offers: custom winding configurations for 36V, 72V, or 96V systems; modified output shafts for direct wheel hub integration; integrated CAN bus communication for vehicle control system integration; custom flange patterns for legacy pump mounting; and compact integrated motor-controller units for space-constrained designs. Engineering samples ship within 3–4 weeks; production quantities above 200 units ship in 4–6 weeks.

Shenghe Motor Lineup for Forklift Applications

Model Power Range Voltage Forklift Function Max Output Torque IP Rating
BL90100–400W24V / 48VEPS steering102 N·mIP54 / IP65
BL104200–1000W24V / 48VPump motor (pallet jack)254 N·mIP54 / IP65
BL120500–2000W24V / 48VTraction drive, pump motor300 N·mIP54 / IP65

Related Pages

Need a BLDC Motor for Your Forklift or Pallet Jack?

Tell us your equipment type, load capacity, target speed, battery voltage, motor function (traction / pump / steering), and expected annual volume. Our material handling drive engineers will recommend the optimal motor-gearbox combination, provide torque/speed calculations matched to your wheel diameter and grade requirements, and deliver 3D STEP models for chassis integration — free of charge for qualified OEM projects with 500+ units per year.

Request Forklift Motor Quote Get Catalog WhatsApp
FAQ

Frequently Asked Questions About BLDC Motors for Forklifts

Answers to common questions from forklift OEM engineers, fleet managers, and material handling equipment designers selecting BLDC drive motors for electric forklifts, pallet jacks, and warehouse trucks.

What size traction motor for an electric forklift?

Pallet jacks (1–2 ton): 1.5–3 kW per drive wheel. Walkie stackers: 2–4 kW. Reach trucks: 4–8 kW (dual motor). Counterbalance forklifts: 8–15 kW total traction. These assume indoor concrete floors, 5–10% grade capability, and a 1.3× safety factor for start-stop intensive duty cycles.

48V or 80V for forklift motors?

Use 48V for total motor power under 12 kW (pallet jacks, small stackers, 3-wheel forklifts). Use 80V for total power above 12 kW (counterbalance forklifts 2+ ton). The key driver is peak current: 80V halves the current draw versus 48V, reducing wiring losses by 75% and keeping connector temperatures within safe limits.

Why is BLDC replacing AC induction in forklifts?

Three reasons: 8–15% longer battery runtime (BLDC maintains 85–90% efficiency at partial load vs 70–80% for induction), 20–30% smaller motor for the same power, and full torque from zero RPM with FOC control (induction motors lose torque below 5–10% of rated speed). The 15–25% higher BLDC motor cost is offset by battery savings within 18–24 months.

How much energy does regenerative braking recover?

Combined traction and hydraulic regeneration recovers 15–25% of total energy consumption per shift. Traction regen alone recovers 10–15% from the 200–500 deceleration events per shift. Hydraulic regen adds another 5–10% by recovering gravitational energy during mast lowering. This often eliminates mid-shift battery swaps.

What motor drives the forklift hydraulic pump?

The pump motor runs at 1800–2500 RPM and drives the gear pump through a direct bell housing coupling (no gearbox). Power: 2–3 kW for pallet jacks, 4–7 kW for counterbalance forklifts. BLDC pump motors with variable-speed control save 15–25% hydraulic energy versus fixed-speed brushed DC pumps.

Key Answers

Short Answers For Generative Search.

Concise answers for search engines and engineers evaluating BLDC motors for electric forklifts, pallet jacks, walkie stackers, and material handling drive systems.

What is the best motor for an electric forklift?

BLDC (brushless DC / permanent magnet synchronous) motors are the best choice for modern electric forklifts. They provide 90–95% efficiency at full load and maintain 85–90% at partial load (where forklifts spend most of their operating time), deliver full rated torque from zero RPM for loaded starts, offer 20–30% smaller volume than equivalent AC induction motors, and enable effective regenerative braking that extends battery runtime by 15–25%. The three motor functions in a forklift — traction drive, hydraulic pump, and EPS steering — all benefit from BLDC technology.

How many motors does an electric forklift have?

A typical electric forklift has three motors: one or two traction drive motors (1.5–15 kW depending on capacity), one hydraulic pump motor (2–7 kW for lift/tilt/side-shift), and one EPS steering assist motor (200–500W). Class III pallet jacks may have only two (traction + pump). Counterbalance forklifts with dual traction motors use electronic differential steering, potentially eliminating the separate steering motor.

What voltage do electric forklift motors use?

Electric forklift voltage depends on equipment class: 24V for pallet jacks (total power under 5 kW), 48V for walkie stackers and small counterbalance forklifts (5–12 kW), and 80V for medium and large counterbalance forklifts (12–25 kW). Higher voltage reduces current draw, wiring losses, and connector heating. The industry is trending toward 48V lithium-ion even for equipment that traditionally used 24V lead-acid.